AMBIENT + EXAM

- Fixtures come in pairs, separate IES files are provided for a Right and a Left fixture as the distribution for each is unique. 
- For Ambient only Illuminance use the AMBIENT Right and Left files only. 
- For Exam Illuminance use the EXAM Right and Left files only. The EXAM files represent the summation of Ambient + Exam, both of which are required to be on to reach the total Exam Function output.


AMBIENT + EXAM + READER

- Fixtures come in pairs, separate IES files are provided for a Right and a Left fixture as the distribution for each is unique. 
- For Ambient only Illuminance use the AMBIENT Right and Left files only. 
- For Exam Illuminance use the EXAM Right and Left files only. The EXAM files represent the summation of Ambient + Exam, both of which are required to be on to reach the total Exam Function output.
- For Reader only Illuminance use the READER Right and Left files only.
- For Ambient + Reader Illuminance use the AMBIENT Right and Left files + READER Right and Left files. First place the AMBIENT files into your layout. Then place the READER to where is overlaps the AMBIENT and top of both fixtures align.


PLEASE NOTE: 
 
- FMA8LE and FMA8LR Ambient performance is the same, therefore FMA8LE IES files can be used for both.  
- Each Right and Left file will need to be imported and placed into AGi32 separately and spaced appropriately per your room layout. 
- When locating any of the files into an AGi32 room, ensure that the fixture Orientation Arrow is pointed towards the Foot of the bed. This will ensure that the photometric web is oriented toward the bed.